Lumseq logoLumseq
Lighting Journal

Product knowledge

DL0398 Step Light Replacement: Match the Cut-Out, Not S/M/L

Compare DL0398 S, M and L cut-outs before replacing a recessed step light. A larger face and the same 5 W rating do not establish a fit in an existing opening.

DL0398 Step Light Replacement: Match the Cut-Out, Not S/M/L

Key takeaways

  • DL0398-S, M and L specify different rectangular cut-outs: 160 × 65, 245 × 45 and 240 × 80 mm. The suffixes do not describe a common mounting interface.
  • For a hypothetical opening A245 × B45 mm, with the first listed cut-out dimension mapped to A and the second to B, DL0398-L requires 35 mm more in direction B. This is an assumed comparison orientation, not an installation drawing.
  • Even a nominal cut-out match is only a first check. Recess depth, fixing, cable entry and the complete outdoor installation detail still require model-specific review.

Separate the visible face from the opening behind it

Do not select a DL0398 replacement by S, M or L alone. Compare the measured existing opening with the cut-out specified for the exact proposed model, in both directions. Then check the complete mounting detail. The outer product dimensions describe a different boundary and cannot establish that a replacement fits the recess.

This matters when the wall finish is already complete. A proposed face can be wider and taller than the visible hole while the required opening behind it has a different shape. Find that mismatch before approving a replacement line on the order.

Existing Lumseq AI design illustration labelled DL0398-S. The wall scene, product details and panel labelled Installed effect are design references, not a photographed installation, dimensional fit check or measured lighting result. The product page asks for manufacturer confirmation of the illustrated identity. Full original poster retained.

Read each DL0398 cut-out as a complete pair

The current Lumseq listing and catalog specification sheet give the following values in millimetres. Dimensions retain the source order. The sheet does not label the axes or give a dimensioned mounting detail, so ask the supplier to map each value to the actual opening and installation orientation.

The M and L cut-out pairs change in opposite directions: 245 × 45 mm versus 240 × 80 mm. The first listed value decreases by 5 mm while the second increases by 35 mm. L’s third listed outer dimension is 60 mm, versus 55 mm for M; do not treat it as a required recess depth. A letter or area comparison cannot describe these interfaces.

Listed modelOuter dimensions (mm)Listed cut-out (mm)
DL0398-S170 × 70 × 55160 × 65
DL0398-M255 × 80 × 55245 × 45
DL0398-L250 × 90 × 60240 × 80

Worked substitution: a 245 × 45 mm existing opening

Assume a survey sketch labels the two directions of an existing rectangular opening A and B, with A = 245 mm and B = 45 mm. For this example only, map the first quoted cut-out dimension to A and the second to B for both proposed models. That mapping must be confirmed on a current installation drawing before a real selection; it is not an installation instruction.

DL0398-M matches the example’s two nominal values under that mapping. M can proceed to mounting-detail review. The actual opening shape and corners, wall condition, recess depth, fixing and cable route can still prevent a suitable installation.

DL0398-L specifies 240 × 80 mm. Under the same assumed mapping, the existing opening is 5 mm greater in direction A but 35 mm short in direction B. The pair is different, even though the listed outer dimensions start with larger numbers than the old opening. Outer dimensions do not resolve the mismatch or prove retention and sealing.

If retaining the wall opening without alteration is a project condition, do not accept L as a matching-cut-out alternative on these figures. Require the supplier to identify the axis mapping and any mounting change. A proposal involving wall work, an adapter or a different arrangement needs a separately reviewed detail; the listing does not authorize an improvised solution.

Proposed modelComparison under the example A/B mappingProcurement decision
DL0398-MA245 × B45 mm matches nominal pairKeep for mounting-detail review
DL0398-LA240 × B80 mm required; existing B is 35 mm shortDo not accept as a matching-cut-out substitution on these figures

Keep the recess condition on the replacement request

Label the two opening directions on the survey sketch and record their measured sizes at the actual location. Add usable recess depth, wall construction and condition, the existing fixing method, cable entry and access. Include photographs after safe access by the responsible installer. Ask the supplier to mark the cut-out dimensions against those same directions; do not derive the mapping or measurements from the AI illustration.

All three listed DL0398 configurations share 5 W, 3000K, AC 100–260V and IP66; finish options are Sand black, Sand white and Sand grey. Those shared entries do not establish mechanical interchangeability, a control method or the required lighting result. Material is not specified in the current listing. Keep the product rating separate from the protection of the completed wall and connection arrangement.

Example enquiry: “Existing opening at wall reference ST-01: A245 × B45 mm, with directions marked on the attached sketch. Please review DL0398-M, listed outer dimensions 255 × 80 × 55 mm and cut-out 245 × 45 mm. Please map these values to our sketch and provide the installation detail and supplied mounting parts. Existing recess, fixing and cable-entry records are attached. The opening is to remain unaltered. Quantity: [enter quantity].”

Send Lumseq the opening sketch, existing mounting photographs and proposed exact model. A quote should identify any deviation from the retained-opening condition before the project team accepts it. Decide fit and mounting first; assess light distribution and the outdoor installation separately.

Frequently asked questions

Questions buyers ask

Can a nominal cut-out match confirm that an outdoor step light will keep the same IP protection?

No. The listed DL0398 product rating is IP66, but matching the opening dimensions does not establish the protection of the completed wall, cable entry, joints or connections. Review the exact model’s installation instructions and the complete mounting and connection detail for the site conditions.

Sources and references

Lumseq DL0398 — current configuration comparisonLumseq DL0398 catalog specification sheet

Talk to the product team

Planning an OEM or commercial lighting order?

Send your application, specification and destination market. We will help narrow the product and sample options.

Discuss on WhatsApp