Key takeaways
- Build a magnetic track order as a complete system: rails, connection parts, feeds, drivers, light modules and controls must be specified together.
- Count each marked layout junction once. In the hypothetical six-segment example, four junctions give two straight, one angle and one T candidate; the T junction is one node, not three connectors.
- Keep geometric quantities separate from exact system approval, stock-rail lengths, electrical sections and spare parts. The current 30 Series listings identify candidate models, but do not establish universal compatibility.
Start with a marked layout and a complete kit
Before comparing magnetic track prices, mark the rail segments and junctions on one drawing revision, count each junction once, and carry those references into the quotation. Then verify the rails, connection parts, feeds, drivers, light modules and controls as one offered system. A total track length alone does not define the parts order.
The worked example below converts a simple branched layout into candidate connection-part quantities. It is a hypothetical counting exercise, not a real project, an installation drawing or an approved electrical bill of materials.
Existing Lumseq AI product-family visualisation labelled 30 SERIES Angle Module. It illustrates the product family and planning context; it is not a photograph, a verified LS0032 configuration drawing or evidence of track fit, current capacity, electrical continuity or a completed project. Full original image retained.
Define the segments before counting the junctions
Assume a plan with a straight main run A–J1–J2–B and a branch from J2 through J3 and J4 to C. The branch turns at J3; J4 stays straight. J2 is a T junction with three incident segments. A, B and C are outer ends. The table fixes every segment boundary so another buyer can reproduce the count.
R1–R6 are six schematic segments, not six purchased stock rails. Assume no extra splice inside any segment for this exercise; actual lengths, stock selection, cutting allowances and any additional joints remain outside this count.
| Schematic segment | Endpoints | Plan relationship |
|---|---|---|
| R1 | A → J1 | Main run |
| R2 | J1 → J2 | Continues straight from R1 |
| R3 | J2 → B | Continues the main run |
| R4 | J2 → J3 | Branch leaving the main run at J2 |
| R5 | J3 → J4 | Turns from R4 at J3 |
| R6 | J4 → C | Continues straight from R5 |
Count nodes, then map candidate 30 Series parts
For the provisional quotation, assume one candidate connection module for each marked junction of the corresponding shape. Count the junction, not its number of arms. This makes J2 one T candidate; it does not add three straight candidates for the three segments meeting there.
The current Lumseq 30 Series listings identify LS0033 as the straight module, LS0032 as the angle module and LS0030 as the T module. All three list DC 48V. Their listed dimensions are 60×30×17 mm, 60×60×17 mm and 90×60×17 mm respectively. These labels and values identify candidates for review; they do not prove the parts fit every 30 mm or 48 V track.
| Node / connected segments | Plan shape | Candidate model | Provisional quantity |
|---|---|---|---|
| J1: R1 + R2 | Straight | LS0033 | 1 |
| J2: R2 + R3 + R4 | T branch | LS0030 | 1 |
| J3: R4 + R5 | Angle | LS0032 | 1 |
| J4: R5 + R6 | Straight | LS0033 | 1 |
| Grouped quotation lines | 2 straight + 1 angle + 1 T | LS0033 ×2; LS0032 ×1; LS0030 ×1 | 4 candidate modules |
Keep drawing revisions attached to the quantity
Suppose revision B splits R5 into two collinear pieces, R5a and R5b, with a new straight junction J5. If every other boundary and junction remains unchanged, the provisional count becomes three straight, one angle and one T: five candidate modules. Total route length might stay the same while the connection-part quantity changes.
Keep the installed candidate quantity, the node references and the drawing revision on the same quotation line. A useful line reads: “Rev A — LS0033 straight-module candidate, quantity 2, at J1 and J4; exact offered-system fit and finish to be confirmed.” For revision B, add J5 and update that line to quantity 3. Record supplier substitutions as separate identified models rather than silently changing the node schedule.
Resolve the system boundaries before releasing the order
The geometric count does not establish electrical continuity through a straight, angle or T module, polarity, permitted orientation, loading, control compatibility or the number of feeds. The public listings reviewed here do not provide an approved wiring arrangement or connector current rating. A T-shaped physical route therefore cannot be assumed to be one electrical section.
Likewise, the three outer ends A, B and C do not determine three feeds or three end caps. Assign the actual feed, termination and mounting accessories using the exact system documentation and project design, keeping their quotation lines separate from the four geometric candidates.
The current track page labels LS0035 as 1 m, LS0036 as 2 m and LS0037 as 3 m, but repeats 1000×30×8 mm across those rows. That source conflict must be resolved before stock-length or cutting calculations. This example uses no length arithmetic and does not convert its six schematic segments into a rail order.
Once the route and component identities are fixed, assess light-module quantities, beam, CCT, glare and colour needs for the application, and assign loads to documented electrical sections. Use the installation and load guides for those separate decisions.
Send a quotation brief that can be checked again
Send the marked drawing and revision, node schedule, exact rail family and installation method, chosen finish, intended application and destination. Ask the supplier to return a complete kit schedule that reconciles every connection candidate with the offered system, then identifies the feeds, drivers, mounting and termination parts, light modules and controls.
For the hypothetical Rev A layout, the connection-part portion starts at LS0033 ×2, LS0032 ×1 and LS0030 ×1, all subject to exact system review. This gives the buyer a traceable starting point for price comparison while keeping unresolved rail lengths and electrical design visible. Preserve the confirmed codes and revision for repeat orders.
Frequently asked questions
Questions buyers ask
How should spare connectors appear on the purchasing specification?
Keep installed quantities and spares on separate lines using the exact approved part codes and finishes. The worked example gives installed candidates only and includes no spare allowance. Agree the spare quantity for the project or distributor stock plan; do not silently add a universal percentage or let spares hide a missing installed junction.
Sources and references
Lumseq 30 Series straight module — LS0033Lumseq 30 Series angle module — LS0032Lumseq 30 Series T module — LS0030Lumseq 30 Series ultra-thin surface trackLumseq magnetic track installation planningLumseq magnetic track load and driver sizingTalk to the product team